Ship-based single-SMR

From Factsheets: Limiting UK Emissions
Revision as of 11:03, 13 December 2019 by Trevor (talk | contribs)
Jump to navigation Jump to search

For smaller cities with populations from around 130,000 up to 400,000 a ship with a single SMR is deployed.

SS SMR1.png


The SMR (I) is designed to operate year-round in CHP mode raising steam (II) to produce electricity via a non-condensing turbine + generator (III, IV) and using the low pressure exhaust steam to heat a district-heating water circuit (V). Any surplus heat in the form of uncondensed steam is removed by the on-board supplementary condensers (VIII) and the cooling circuit (IX) for these is cooled, in turn, by water drawn from the estuary (X). Hot condensate from the hot well (VII) is pumped (VI) back through the boiler (II) to complete the closed-loop steam circuit.

DETAIL SMR1.png


T/C P/Bara h s quality Work in Heat in Work out Heat out (rejected)
Feed Water 45.0 1 188.5 0.6386 #Subcooled liquid
Pump Isentropic compression 45.1 40 192.4 0.6386 #Subcooled liquid 3.9
Heat to Bpt 250.4 40 1087.5 2.7968 0
Water - steam 250.4 40 2800.8 6.0696 1
Degrees superheat 39.6
Steam 290.0 40 2933.0 6.3133 #Superheated vapor 2740.5
Ideal expansion 45.8 0.1 1998.4 6.3133 0.7553
Real expansion IE=0.85 45.8 0.1 2138.6 6.7528 0.8139 794.4
Condense & subcool 45.0 0.1 188.4 0.6386 #Subcooled liquid 1950.2
Work eff. Heat eff.
28.8% 0.0%
say 27.5% 0%
110 MWe 0 MWt